Uw health orthopedics in madison wisconsin provide comprehensive care for patients with hip pain ranging from nagging pain that may benefit from non surgical rehabilitation to chronic debilitating pain caused by arthritis that can be treated with total hip replacement surgery.
Taper lock hip replacement.
Taperloc complete hip system over the past 26 years the taperloc hip stem has become the industry standard in cementless hip arthroplasty 1 combining this unmatched clinical success with biomet s commitment to product innovation the taperloc complete hip system has been introduced with design enhancements that.
Used in hip replacement surgeries the stryker lfit v40 femoral heads are one component of two that are implemented during the artificial replacement the other component being femoral necks.
Hip implant devices like the stryker lfit v40 hip implant use a ball and socket connection to mimic the natural hip joint.
This is known as a taper lock system.
The old implant must be removed and a new metal stem must be pounded into the femur.
The femoral component is comprised of several different parts including a stem inserted into the bone and a ball head that sits on top.
The taper lock is the part of the hip device that connects the femoral head to the femoral neck during total hip replacement procedures.
In a total hip replacement there is typically a femoral component that replaces the femur thigh bone.
Taper lock failure is cited as a major reason for hip implant failure of the stryker metal v40 device.
The ball and stem are joined at the femoral neck.
The taperloc complete hip system has since become the industry standard in cementless hip arthroplasty 1 combining unmatched clinical success with zimmer biomet s commitment to product innovation the taperloc complete hip system has design enhancements that are intended to help surgeons restore leg length stability offset and range of motion accurately and consistently.
Taperloc complete hip system implants.
Type 1 taper pps coating product.
Revision surgery is physically traumatic especially for older patients.
Both the femoral heads and the femoral necks are made of metal and the complaints stryker has received concern the taper lock a device that connects.
In contemporary total hip arthroplasty tha modular devices often are used that consist of a femoral stem and head joined by a tapered interlock morse type taper that is assembled intraoperatively.
Taper lock failures also known as trunnionosis are recognized as a growing cause of hip replacement failures there is no good solution.
Number high offset.